BXRRS - UNFACED METAL BUILDING INSULATION 202
- MSDS: BXRRS
- Manufacturer: CERTAINTEED CORP
- Product Name: UNFACED METAL BUILDING INSULATION 202
- National Stock Number: 5640-00N060251
Product Identification
Product ID:UNFACED METAL BUILDING INSULATION 202
MSDS Date:03/25/1993
FSC:5640
NIIN:00N060251
MSDS Number: BXRRS
Responsible Party
US
Emergency Phone: 215-341-7000
Info Phone: 215-341-7677
Cage: CERTA
Contractor
Telephone: (215) 341-7000
Cage: CERTA
Ingredients
>2550F,>1399C.
RTECS: LK3651000
Fraction By Weight: 58-97%
OSHA PEL 15 MG/M3 (MFR)
ACGIH TLV: 10 MG/M3 (MFR)
UREA EXTENDED PHENOL-FORMALDEHYDE RESIN CURED; (PHENOL
CAS: 25104-55-6
Fraction By Weight: 3-17%
OSHA PEL N/K
ACGIH TLV: N/K
PARAFFIN; (CHLORINATED PARAFFINS)
CAS: 8002-74-2
RTECS: RV0350000
Fraction By Weight: 7%
OSHA PEL 2 MG/M3 (FUME)
ACGIH TLV: 2 MG/M3 (FUME)
ACETIC ACID ETHENYL ESTER POLYMER WITH ETHENE;
CAS: 24937-78-8
Fraction By Weight: 11%
OSHA PEL N/K
ACGIH TLV: N/K
NITROGEN & NITROGEN-OXYGEN COMPOUNDS.
RTECS: 9999999ZZ
INSULATION WILL BEGIN TO THERMALLY DECOMP
RTECS: 9999999ZZ
AT ABOUT 300C-350C (570-660F) RELS HYDROGEN FLUORIDE.
RTECS: 9999999ZZ
HYDROGEN CHLORIDE, HYDROGEN FLUORIDE & SULFUR DIOXIDE
RTECS: 9999999ZZ
SIGNIFICANT EXCESS IN RESP CANCER. AUTHORS
RTECS: 9999999ZZ
OF LITTLE PRACTICAL SIGNIFICANCE" & WAS SUPPORTED BY
RTECS: 9999999ZZ
MAN-MADE VITREOUS FIBER. SM STUDY OF CANADIAN GLASS
RTECS: 9999999ZZ
INCR IN LUNG CANCER DEATHS. INTERPRETATION OF INFO
RTECS: 9999999ZZ
BTWN EXCESS LUNG CANCER & LGTH OF TIME SINCE FIRST
RTECS: 9999999ZZ
IS RELATED TO ANY FACTORS IN WORK ENVIRON. BASED
RTECS: 9999999ZZ
MANDATORY CLASSIFICATION PROTOCOL, IARC CLASSIFIED
RTECS: 9999999ZZ
IARC REGARDS IT AS PRUDENT TO TREAT MATL FOR WHICH
RTECS: 9999999ZZ
IS A POSSIBLE CARCINOGEN TO HUMANS.
RTECS: 9999999ZZ
TYPE H FILTER (HEPA).
RTECS: 9999999ZZ
INSULATION, WEAR LONG SLEEVES & CAP.
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE:EXPOS TO FIBER GLASS MAY CAUSE
TEMPORARY SKIN, EYE & UPPER RESP IRRIT. CHRONIC:EXTENSIVE
MED-SCIENTIFIC RESEARCH HAS BEEN CONDUCTED REGARDING HLTH ASPECTS
OF FIBER GLASS OVER PAST 50 YRS. IN IAR C ANIMAL EXPTS IN WHICH
GLASS WOOL FIBERS WERE ARTIFICIALLY INJECTED/SURGICALLY IMPLANTED
IN ANIMALS' (EFTS OF OVEREXP)
Explanation of Carcinogenicity:GLASSWOOL, IARC GROUP 2B, VOL 43, P 152,
1988.
Effects of Overexposure:HLTH HAZ:LUNGS, TUMORS WERE PRDCD. SUCH PROCS
BY-PASSED NORMAL BODY DEFENSE MECHS. EXPTS ARE INAPPROP FOR
EVALUATING MANY ASPECTS OF ENVIRON HAZ, SINCE THEY CIRCUMVENT THOSE
FACTORS THAT MIGHT INHIBIT /ENHANCE EXPOS THRU NATRL RTES.
EPIDEMIOLOGY STUDY OF 11,380 MAN-MADE VITREOUS WORKERS REVEALED SM
STATISTICAL (ING 9)
Medical Cond Aggravated by Exposure:PRE-EXISTING CONDITIONS WHICH MAY
BE AGGRAVATED BY MECHANICAL IRRITANTS UPON INHALATION OR SKIN
CONTACT.
First Aid
First Aid:INHAL:REMOVE FROM EXPOS. REMOVE TO FRESH AIR, ADMIN OXYGEN &
GET MED HELP. GET MED HELP IF IRRIT PERSISTS. EYE:FLUSH WELL
W/RUNNING WATER FOR AT LST 15 MINS. GET MED HELP IF IRRIT PERSISTS.
SKIN:CLEAN SE W/SOAP & WATER. GET MED HELP IF IRRIT PERSISTS.
INGEST:CONSULT MD IF UNUSUAL RXN IS NOTED. INFO FOR MED
PRACTITIONERS:SKIN IRRIT RESPONDS WELL TO MILD HYDROCORTISONE
CREAM.
Fire Fighting
Extinguishing Media:USE THAT WHICH IS APPLICABLE TO SURROUNDING FIRE.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . TREAT AS RESIDENTIAL BUILDING MATERIALS.
Unusual Fire/Explosion Hazard:FACINGS ON THESE PRODS MAY BURN. CARE
SHOULD BE TAKEN NOT TO LEAVE FACING EXPOS WHEN WORKING CLOSE TO
OPEN FLAME. THESE PRODS CONTAIN CURED PHENOLIC- (SUPDAT)
Accidental Release
Spill Release Procedures:VACUUM DUST DEPOSITS. CLEAN AREA W/VACUUM OR
WET METHODS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE UNDER COVER TO PROTECT PRODUCT.
AVOID SPREAD OF FIBER GLASS DUST.
Other Precautions:WARNING:CONTAINS FIBER GLASS WOOL, POSSIBLE CAUSE OF
CANCER IF INHALED. FIBER GLASS WOOL INSULATION MAY CAUSE SKIN, EYE
& RESP IRRIT. FOR ADDNL PROD SFTY INFO, INCL NIOSH/MSHA APPRVD DUST
RESP & MSDS, CALL (215)341-7677.
Exposure Controls
Respiratory Protection:WEAR NIOSH/MSHA APPRVD RESPS WHEN HNDLG &
APPLYING FIBER GLASS INSULATION PRODS I/A/W FOLLOWING NIOSH-BASED
EXPOS GUIDELINES. <10 TIMES NIOSH REL - 3M 8710/3M 9900 (OR EQUIV);
<50 TIMES NIOSH REL - MS A ULTRA TWIN FULL FACE RESP W/ (ING 18)
Ventilation:PROVIDE GENERAL &/OR LOCAL EXHAUST VENTILATION TO CONTROL
AIRBORNE DUST LEVELS BELOW EXPOSURE LIMITS.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA . WHEN HANDLING &/OR APPLYING THIS (ING 19)
Work Hygienic Practices:BATHE W/SOAP & WARM WATER. WASH WORK CLOTHES
SEPARATELY & RINSE WASHER AFTER USE.
Supplemental Safety and Health
APPEAR/ODOR:W/KRAFT, ALUMINUM FOIL, VINYL/COMBINATION THEREOF. SOME
PRODS MAY HAVE COATING; FAINT RESIN ODOR. EXPLO HAZ:BASED BINDER.
BINDER & KRAFT FACING IN FIRE SITUATION MAY EMIT TOX FUMES & SMOKE
CNTNG CARBON DIOXIDE, CARBON MONOXIDE & MOLECULAR FRAGMENTS OF
HYDROCARBON PARTICULATES, CARBON-HYDROGEN- (ING 5)
Chemical Properties
Boiling Pt:B.P. Text:SEE ING 1
Melt/Freeze Pt:M.P/F.P Text:SEE ING 1
Spec Gravity:SEE ING 1
Solubility in Water:SMALL.
Appearance and Odor:YELLOW FIBERS ASSEMBLED INTO TUBES,
BLANKETS/BOARDS. PRODS MAY BE FACED (SUPDAT
Stability
Stability Indicator/Materials to Avoid:YES
HYDROFLUORIC ACID.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:VINYL FACINGS MAY THERMALLY DECOMPOSE
AT ABOUT 250C(500F) & RELS HYDROGEN CHLORIDE. AWJ JACKETING ON PIPE
(ING 6)
Disposal
Waste Disposal Methods:SCRAP MATERIAL SHOULD BE DISPOSED OF IN A
SANITARY LANDFILL I/A/W FEDERAL, STATE & LOCAL REGULATIONS. WASTE
IS NOT HAZARDOUS AS DEFINED BY RCRA (40 CFR 261).
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.